Light sourcesOcean Optics
Sources for illumination cover various ranges to enable absorbance, reflectance, and fluorescence measurements from deep-UV to NIR. Compact Light-emitting diodes produce output for fluorescence measu ...
Read more ...
Sources for illumination cover various ranges to enable absorbance, reflectance, and fluorescence measurements from deep-UV to NIR. Compact Light-emitting diodes produce output for fluorescence measurements.
  • Deuterium light sources: Used most often for UV absorbance and reflectance measurements.

  • Combination Deuterium and Tungsten light sources: Used as a single illumination sources for measurements across broad wavelength ranges.

  • Pulsed Xenon Lamps: Used as long life sources for absorbance, reflectance and fluorescence measurements, and for measuring optically or thermally labile samples.

  • Tungsten Halogen light sources: Used most often as standard VIS-NIR light sources for absorbance, reflectance of solid objects, and color measurements.

  • Light emitting diode: Used as excitation sources for fluorescence. Feature minimal warm-up and high stability. Power is lower and spectral width is wider than with lasers.
Overview_ Light Sources.pdf
Light Sources_ Absolute Spectral Output.pdf
Ocean Optics
Light sources
Overview_ Light Sources.pdf
Light Sources_ Absolute Spectral Output.pdf
Radiometric Calibration SourcesOcean Optics
Radiometric Calibration Standard: VIS-NIR: Each of these radiometric sources comes with a regulated 12VDC power supply. Also included certificate and a diskette with data files foe use with our irradi ...
Read more ...
Radiometric Calibration Standard: VIS-NIR: Each of these radiometric sources comes with a regulated 12VDC power supply. Also included certificate and a diskette with data files foe use with our irradiance software.
Calibrated with Fiber & Cosine diffuser is designed for calibrating the absolute spectral response of a complete system consisting of a spectrometer and an optical fibrer and/ or a cosine corrector.

Calibrated for use with intergrating sphere:is designed for calibrating the absolute spectral response of a system that uses the fibre optic integrating sphere as the sampling optic.

Recalibrating your source
The calibrated sources provide 50 hours of operation before in-house recalibration is necessary.

In-House Calibration
If you do not want to purchase one of these calibration sources, an in-house calibration service for 300-1500nm is available.
Radiometric Calibration Standard.pdf
Specifications:
  • Power comsumption: 600mA @12VDC
  • Spectral range: 300-1050nm ( calibrated)
  • Power output: 6.5Watts
  • Recalibration: required after 50 hours of oeration
  • Bulb colour temperature: 3100K
  • Output regulation: 0.2% voltage
  • Time to stabilized output: ~30 minutes
Ocean Optics
Radiometric Calibration Sources
Radiometric Calibration Standard.pdf
  Photonics    